SciELO - Scientific Electronic Library Online

 
vol.6 número4Aneurisma degenerativo da artéria carótida interna associado a disfagiaFístula Aorto-cava em doente com rotura de aneurisma da aorta abdominal índice de autoresíndice de assuntosPesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Não possue artigos similaresSimilares em SciELO

Compartilhar


Angiologia e Cirurgia Vascular

versão impressa ISSN 1646-706X

Angiol Cir Vasc v.6 n.4 Lisboa dez. 2010

 

Preservação das artérias hipogástricas com endoprótese ramificada no tratamento endovascular de aneurismas aorto-ilíacos.

 

Emanuel Dias*, Gonçalo Alves** Leonor Vasconcelos***, Aragão de Morais****, João Albuquerque Castro*****, Luís Mota Capitão ******

Hospital de Santa Marta, EPE Serviço de Angiologia e Cirurgia Vascular (Director: Dr.L. Mota Capitão)

* 5ºAno do Internato Médico em Angiologia e Cirurgia Vascular

** 3ºAno do Internato Médico em Angiologia Cirurgia Vascular

***Assistente Hospitalar de Angiologia e Cirurgia Vascular

****Assist Hospitalar Grad. de Angiologia e Cirurgia Vascular

***** Chefe de Serviço de Angiologia e Cirurgia Vascular

***** Chefe de Serviço de Angiologia e Cirurgia Vascular

 

RESUMO

Introdução: Os doentes com indicação para tratamento endovascular de aneurismas da aorta abdominal (EVAR) apresentam frequentemente artérias ilíacas comuns ectasiadas ou aneurismáticas, o que impossibilita a sua utilização como zona de encoragem distal da endoprótese. Em cerca de 15 a 30% dos casos pode existir necessidade de oclusão/embolização de uma ou de ambas as hipogástricas, com extensão da endoprótese para a artéria ilíaca externa. Isto tem sido associado a casos de claudicação glútea, isquémia intestinal, deficits neurológicos, e de disfunção vesical, intestinal e eréctil. O uso de endopróteses com ramo para a artéria hipogástrica apresenta-se como uma recente inovação que permite a preservação desta artéria e evitar estas complicações.

Caso clínico: Homem de 63 anos, com antecedentes de cirurgia aórtica com interposição protésica aorto-aórtica em 2008 por aneurisma da aorta abdominal (AAA) infra-renal, admitido para tratamento endovascular de aneurisma das artérias ilíaca comum e hipogástrica direitas, com 3,3 cm de maior diâmetro. O doente foi submetido a colocação por via femoral de endoprótese Zenith® ramificada para bifurcação ilíaca com preservação da artéria hipogástrica.

Conclusões: A utilização de endopróteses ramificadas para a bifurcação ilíaca durante a correcção endovascular de aneurismas aorto-ilíacos para ser uma forma segura e pouco complexa de garantir a preservação das artérias hipogástricas e minimizar as complicações associadas à sua oclusão.

Palavras-Chave: Aneurisma da aorta, Tratamento endovascular, Endoprótese ramificada ilíaca

 

The Zenith iliac bifurcation Device (IBD) for preservation of the internal iliac arteries during endovascular repair of aortic-iliac aneurysms.

ABSTRACT

Introduction: A significant portion of patients presenting for endovascular aneurysm repair of the abdominal aorta (EVAR) have aneurysmatic or ectasied common iliac arteries, raising distal anchorage issues. In these cases, it may be necessary occlusion / embolization of one or both hipo gastric arteries with extension of the endoprothesis to the external iliac artery. This procedure has been associated to gluteal claudication, intestinal ischemia, vesical and intestinal disfunction, neurologic deficits and impotence. The use of branched endoprothesis with preservation of the hypgastric artery is a recente innovation to reduce such complications.

Clinical case: A 63 year-old male, previously submitted to an open repair of an abdominal aortic aneurysm with an aorto-aortic prothesis, was admitted for endovascular treatment of an aneurysm of the right common and internal iliac arteries with 3,3cm. A Zenith® branched endoprothesis with a branch to the iliac bifurcation was deployed via right femoral access, thus assuring preservation of the hypogastric artery.

Conclusion: Hypogastric preservation necessity during EVAR in aorto-iliac aneurysms may be achieved in a secure and simple way through the placement of endoprothesis to the iliac bifurcation.

Key Words: Aortic aneurysms, Endovascular treatment, Iliac branch device |

 

Texto completo disponível apenas em PDF.

Full text only available in PDF.

 

BIBLIOGRAFIA

1 Lee WA, O’Dorisio J, Wolf YG, Hill BB, Fogarty TJ, Zarins CK.Outcome after unilateral hypogastric artery occlusion during endovascular aneurysm repair. J Vasc Surg 2001;33:921-6.         [ Links ]

2 Iliopoulos JI, Hermreck AS, Thomas JH, Pierce GE. Hemodynamics ofthe hypogastric arterial circulation. J Vasc Surg 1989;9:637-41.

3 Armon MP, Wenham PW, Whitaker SC, Gregson RH, Hopkinson BR. Common iliac artery aneurysms in patients with abdominal aortic aneurysms Eur J Vasc Endovasc Surg. 1998 Mar;15(3):255-7

4 Boules TN, Selzer F, Stanziale SF, Chomic A, Marone LK, Dillavou ED, Makaroun MS. Endovascular management of isolated iliac artery aneurysms. J Vasc Surg. 2006 Jul;44(1):29-37.

5 Richardson JW, Greenfield LJ. Natural history and management of iliac aneurysms. J Vasc Surg 1988;8:165-71.

6 Rayt HS, Bown MJ, Lambert KV, Fishwick NG, McCarthy MJ, London NJ, Sayers RD. Buttock claudication and erectile dysfunction after internal iliac artery embolization in patients prior to endovascular aortic aneurysm repair. Cardiovasc Intervent Radiol. 2008 Jul-Aug;31(4):728-34

7 Mehta M, Veith FJ, Ohki T, Cynamon J, Goldstein K, Suggs WD, et al. Unilateral and bilateral hypogastric artery interruption during aortoiliac aneurysm repair in 154 patients: a relatively innocuous procedure. J Vasc Surg 2001;33:S27-32.

8 Lin PH, Bush RL, Chaikof EL, Chen C, Conklin B, Terramani TT, et al. A prospective evaluation of hypogastric artery embolization in endovascular aortoiliac aneurysm repair. J Vasc Surg 2002;36:500-6.

9 Lee WA, Nelson PR, Berceli SA, Seeger JM, Huber TS. Outcomes afterhypogastric artery bypass and embolization during endovascular aneurysm repair. J Vasc Surg 2006;44:1162-9.

10 Mehta M, Veith FJ, Darling RC, Roddy SP, Ohki T, Lipsitz EC, Paty PS, Kreienberg PB, Ozsvath KJ, Chang BB, Shah DMEffects of bilateral hypogastric artery interruption during endovascular and open aortoiliac aneurysm repair. J Vasc Surg. 2004 Oct;40(4):698-702.

11 Yano OJ, Morrissey N, Eisen L et al (2001) Intentional iliac artery occlusion to faciliate endovascular repair of aortoiliac aneurysms. J Vasc Surg 34:204–211

12 Minion DJ, Xenos E, Sorial E, Saha S, Endean ED. The trifurcated endograft technique for hypogastric preservation during endovascular aneurysm repair. J Vasc Surg. 2008 Mar; 47(3):658-61.

13 Delle M, Lönn L, Wingren U, Karlström L, Klingenstierna H, Risberg B, Grahn P, Nyman U. Preserved pelvic circulation after stent-graft treatment of complex aortoiliac artery aneurysms: a new approach. J Endovasc Ther. 2005 Apr;12(2):189-95.

14 Bergamini TM, Rachel ES, Kinney EV. et al. External iliac artery-to-internal iliac artery endograft: a novel approach to preserve pelvic inflow in aortoiliac stent grafting. J Vasc Surg. 2002;35:120–124.

15 Serracino-Inglott F, Bray AE, Myers P. Endovascular abdominal aortic aneurysm repair in patients with common iliac artery aneurysms – initial experience with the Zenith bifurcated iliac side branch device. J Vasc Surg 2007;46:211-7.

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons